Reservior/Wet Well
|
| |

 |
Between pours, apply Xypex Concentrate slurry to all joint surfaces at the
rate of 2.0 lb./sq. yd. (1.0 kg/m2).
|
 |
In sealing strip, apply one coat of Xypex Concentrate at the rate of
1.5 lb./sq. yd. (0.8 kg/m2), then fill slot to surface with Xypex Concentrate
in Dry-Pac form.
|
 |
To interior walls, slab and exterior of roof area, apply one slurry coat of
Xypex Concentrate at the rate of 1.25 to 1.5 lb./sq. yd. (0.65 to 0.8 kg/m2).
After the Concentrate has set, but while it is still "green", apply a coat of
Xypex Modified at the rate of 1.25 to 1.5 lb./sq. yd. (0.65 to 0.8 kg/m2).
Note: For horizontal surfaces in new construction, Xypex Concentrate DS-1
can be used in lieu of standard Xypex coating system.
|
|
Schematic diagram shows Xypex application only and does not depict the standard requirements for waterstops or expansion joint sealant.
The specifier can consider the alternative use of Xypex Dry Shake or Xypex Admix, where applicable.
|
| Refer to Standard Specifications for further information. |